Electronic SystemS TF-108 Manual del operador

Busca en linea o descarga Manual del operador para Marcos de fotos digitales Electronic SystemS TF-108. Electronic SystemS TF-108 Operator`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Operator’s

Operator’s Manual TF-DSQ Probe Calibration and Deskew Fixture

Pagina 2 - Deskew Fixture

Operator's Manual 10 TF-DSQ-OM-E RevC Assembling the TF-DSQ fixture See the fixture overview to identify individual components. System assembly

Pagina 3 - Warranty

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 11 TF-DSQ Oscilloscope Connection The TF-DSQ fixture is connected to either an unused os

Pagina 4 - TABLE OF CONTENTS

Operator's Manual 12 TF-DSQ-OM-E RevC Probe Connection to TF-DSQ The TF-DSQ provides multiple probe connectors for various kinds of probes. Prob

Pagina 5

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 13 Figure 4-3. Differential Probe Properly Connected to the Fixture (Browsing Configur

Pagina 6 - TF-DSQ Overview

Operator's Manual 14 TF-DSQ-OM-E RevC Probe Calibration Probe Calibration Menu Accessing the Probe Calibration Menu The probe calibration menu c

Pagina 7

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 15 Note: The Cal Skew Ref field (and others) shows EXT for External Trigger Input. This

Pagina 8 - TF-DSQ Connections

Operator's Manual 16 TF-DSQ-OM-E RevC PROBE DESKEW INFORMATION The probe deskew information contains the measured skew between the probe in the

Pagina 9 - TF-DSQ Fixture Elements

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 17 Basic Probe Calibration The TF-DSQ fixture is used to calibrate probes. Prior to begi

Pagina 10 - Operator's Manual

Operator's Manual 18 TF-DSQ-OM-E RevC Deskew Only Pressing this button performs only the deskew calibration of the probe on the specified channe

Pagina 11

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 19 Common Mode Voltage Selection The TF-DSQ fixture calibrates probes differentially or

Pagina 12 - Probe Connection to TF-DSQ

TF-DSQ Probe Calibration and Deskew Fixture Operator's Manual July, 2009

Pagina 13 - TF-DSQ-OM-E RevC

Operator's Manual 20 TF-DSQ-OM-E RevC Two channels are properly deskewed relative to each other when the difference between the deskew values en

Pagina 14 - Probe Calibration

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 21 The following example illustrates this scenario: Two probes are used in a system. The

Pagina 15 - PROBE DC INFORMATION

Operator's Manual 22 TF-DSQ-OM-E RevC Deskew Risetime Adjustment Theory Two scenarios require adjustment of the deskew values to account for ris

Pagina 16

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 23 Now, let's assume that these probes are applied to signals with the same risetim

Pagina 17 - Basic Probe Calibration

Operator's Manual 24 TF-DSQ-OM-E RevC The TF-DSQ fixture, in accordance with the philosophy of requiring only one calibration in the fixture, ha

Pagina 18

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 25 The gain and offset correction applied during DC calibration affects the voltage mea

Pagina 19 - Theory of Operation

Operator's Manual 26 TF-DSQ-OM-E RevC In this case, the outer conductor connects the oscilloscope's ground to the circuit's ground, an

Pagina 20

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 27 Despite differential probes measuring differentially, they can be used to measure com

Pagina 21

Operator's Manual 28 TF-DSQ-OM-E RevC Operating Environment Before using your accessory, ensure that its operating environment will be maintaine

Pagina 22

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 29 Electromagnetic Emissions:  EN 55011/A2:2002, Radiated and conducted emissions (Cla

Pagina 23

LeCroy Corporation 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 578-6020, Fax: (845) 578 5985 Warranty LeCroy warrants this os

Pagina 24 - DC Calibration Theory

Operator's Manual 30 TF-DSQ-OM-E RevA Index C calibration: probe, 13 P probe calibration, 13 T TF-DSQ, 5 absolute skew, 19 advanced probe calibr

Pagina 25 - Probing Basics

Thank you for purchasing a TF-DSQ Probe Calibration and Deskew Fixture.

Pagina 26

Operator's Manual iv TF-DSQ-OM-E RevC TABLE OF CONTENTS TF-DSQ Overview ...

Pagina 27

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC v Safety Precautions ...

Pagina 28 - CE Declaration of Conformity

Operator's Manual 6 TF-DSQ-OM-E RevC TF-DSQ Overview Probe Calibration with the TF-DSQ Fixture The TF-DSQ fixture is used in conjunction with th

Pagina 29 - Low-Voltage Directive

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 7 Probe Calibration Steps with the TF-DSQ Fixture Probe calibration is accomplished with

Pagina 30

Operator's Manual 8 TF-DSQ-OM-E RevC TF-DSQ Connections TF-DSQ Fixture Overview The TF-DSQ fixture comes in a soft case containing a CD with .pd

Pagina 31 - TF-DSQ Probe Calibration

TF-DSQ Probe Calibration and Deskew Fixture TF-DSQ-OM-E RevC 9  A ProLink extender  A BNC to SMA adapter (not pictured) TF-DSQ Fixture Elements